Plastic Cuvettes for Spectrophotometer

Plastic cuvettes for spectrophotometers are essential in modern laboratories for accurate optical measurements. These cuvettes, made from materials like polystyrene and quartz, are perfect for light absorption and emission applications.

Essential products in this category include square spectrophotometer cells designed for precise optical work, ensuring consistent results in spectrophotometry. Polystyrene fluorometry cuvettes are specialized for fluorescence measurements and can offer high clarity and minimal interference.

Although primarily for nuclear magnetic resonance, NMR tubes are also essential in certain optical studies. Semi-microcell experiments may require smaller sample volumes to enhance measurement accuracy and reduce lab waste.
Source lamps are also essential as they provide the light source needed for all forms of spectrophotometric analysis.

Each product, from micro quartz cuvettes to macro cells, is crafted to assist with the precise and efficient analysis of samples. Plastic cuvettes for spectrophotometers have varied designs and functions and are indispensable for accurate optical measurements in various applications.

Compare Tool

Select up to 3 products

HomeAll Products

Spectrophotometer Cells/Cuvettes

1 - 32 of 284
Sort
View
Show
  • quick-ship

    labForce® (powered by Thomas Scientific)

    Square, 10 mm Light Path Cells Outside dimensions approximately 12.5 x 12.5 x 46 mm high Light path: 10 mm, ±0.01mm Teflon® cover included Matched sets are supplied in cushioned storage box Cell bodies are of fused-wall construction Cells are usable in spectral…

  • Disposable Polystyrene Cuvettes Convenient and affordable Save time with no cleaning required Prevent cross-contamination Useable in the range of 340 to 750 nm Tight dimensional tolerances ensure high reproducibility from package to package. 10 mm path length; 12.5 x 12.5…

  • MilliporeSigma

    CAS Number: 67-66-3 UN Number: UN1888 Solubility: 8 g/l (20°C) Melting Point: -63°C Molar Mass: 119.38 g/mol Boiling Point: 61°C (1013 hPa) Vapor Pressure: 211 hPa (20°C) Refractive Index: 1.45 Density: 1.48 g/cm3 (20°C)

  • DWK Life Sciences (Kimble)

    100% gauged for wall thickness, concentricity and camber specifications Attached polyethylene caps Sandblasted marking spot OD 3.0124 (+0.00/-0.013) mm ID 2.4003 (+0.013/+0.00) mm Wall thickness 0.284 mm Manufactured from 33 expansion, low extractable borosilicate glass conforming…

  • Agilent Technologies

    Stoppered with PTFE stopper supplied, Top section of the cell features two self-masking black walls and two translucent side walls, z height 20mm, 1/pk. Compatible with Agilent Cary 50/60 UV-Vis spectrophotometers. This product is only available to U.S. Domestic Customers. For research use…

  • 10mm path length UV grade acrylic Volume: 2.5ml 2 Clear Sides Qty: 500

  • Spectrofluorometer Cells With polished bottom for excitation through floor of cell Minimum working capacity 3 mL Cells can also be used for absorption measurements through 10 mm light path Cells have all four sides and bottom polished; 8429N30 furnished with Teflon cover, N19…

  • Reliable, Reusable Glass Cuvettes. The Standard Q macro cuvette with an optical path length of 10 millimeters is made of fused quartz glass and comes in a matching pair. For measurements in the ultraviolet and visible range with a wavelength between 200 nm – 2500 nm. Accuracy by…

  • A wide selection of cells to meet the demanding specifications of UV/VIS spectrophotometers. All cells are fire-fused so they can be cleaned repeatedly and there are no seams or joints to lock in air. 100% handcrafted and individual inspection guarantees the highest quality levels and excellent performance.

  • A wide selection of cells to meet the demanding specifications of UV/VIS spectrophotometers. All cells are fire-fused so they can be cleaned repeatedly and there are no seams or joints to lock in air. 100% handcrafted and individual inspection guarantees the highest quality levels and excellent performance.

  • Agilent Technologies products are intended for sale/shipment within the US only. International customers should contact their local Agilent Technologies distributor to place orders for Agilent Technologies products.

  • DWK Life Sciences (Kimble)

    100% gauged for wall thickness, concentricity and camber specifications Attached polyethylene caps Sandblasted marking spot OD 3.0124 (+0.00/-0.013) mm ID 2.4003 (+0.013/+0.00) mm Wall thickness 0.284 mm Manufactured from 33 expansion, low extractable borosilicate glass conforming…

  • Agilent Technologies

    M6 threaded inlet and outlet ports, inlet/outlet tubes 400 mm length, Compatible with Agilent Cary 50/60 UV-Vis spectrophotometers. Application: For UV-Vis & UV-Vis-NIR Systems This product is only available to U.S. Domestic Customers. For research use only, not to be used in diagnostic procedures.

  • These precision 10 mm diameter NMR tubes are made from quality Pyrex® borosilicate glass for compatibility with ground joints, valves, and vacuum racks. Made using precision bore tubing manufacturing techniques proven most reliable in NMR applications. They have an O.D. of 10.00 + 0.000-0.013mm…

  • Agilent Technologies

    M6 threaded inlet and outlet ports, inlet/outlet tubes 400 mm length, Compatible with Agilent Cary 50/60 UV-Vis spectrophotometers. Application: For UV-Vis & UV-Vis-NIR Systems This product is only available to U.S. Domestic Customers. For research use only, not to be used in diagnostic procedures.

  • This range of Micro Fluorometer cells has been specifically designed by Starna for use with the FCA range of adaptors listed below. The adaptor locates the square cross section cell accurately in the center of the instrument cell compartment. Therefore, for a given path length, the cell is…

  • Spectrosil® Far UV Quartz windows, Useable range: 170 to 2700 nm Dual path length cells Types 52 and 53 allow for both fluorescence and absorbance measurements to be made with small volumes with a choice of two path lengths, dependent on the orientation of the cell in the cell holder. All…

  • 10 mm diameter with 0.60 mm wall thickness ASTM type I Borosilicate glass Concentricity and camber tolerances are strictly maintained for superior performance. Shimming that may have been required with other manufacturers' tubes may no longer be necessary. All tubes are supplied with end…

  • A wide selection of cells to meet the demanding specifications of UV/VIS spectrophotometers. All cells are fire-fused so they can be cleaned repeatedly and there are no seams or joints to lock in air. 100% handcrafted and individual inspection guarantees the highest quality levels and excellent performance.

  • DWK Life Sciences (Kimble)

    Designed to improve the safety of sample handling for the investigation of volatile, air-sensitive and toxic compounds Precision grade NMR tubes Available in 7, 8 and 9 inch lengths Condensing takes place directly into the NMR tube using vacuum techniques. HI-VAC® valve allows…

  • Agilent Technologies

    The Agilent Technologies neutral density screen is useful for the analysis, diagnostics, calibration and monitoring of various chemical samples in laboratories and research facilities. This product is only available to U.S. Domestic Customers. For research use only, not to be used in…

  • Agilent Technologies

    Allows transmittance measurements of solid samples at various incident angles. The sample can be positioned through 360 degrees to the incident beam and is selectable to 1 degree. Application: For External Diffuse Reflectance Accessory (DRA) For Agilent Cary 4000/5000/6000 UV-Vis This product is…

  • Agilent Technologies

    The macro cell which is defined by DIN 58963 as a rectangular cell with an inner width greater than 5 mm has emerged as the standard for photometry. The most widely used macro cell is a rectangular cell with outer dimensions of 45 x 12.5 mm (height x width). The length of the cell is dependent on…

  • Agilent Technologies

    The Agilent Technologies filter kit is used in linearity calibration routines, for proper instrument and DRA calibration. It is compatible with Cary 5/500 systems. Application: For Cary 5/500, Used With Linearity Calibration Routines to Ensure Instrument & DRA are Correctly Calibrated This…

  • Disposable cuvettes with four optically clear sides from BRAND for use in fluorescence applications when results count.  Available in high quality polystyrene for measurements from 340nm to 800nm, as well as a proprietary polymer for precise measurements in both the visible and UV-range…

  • Agilent Technologies

    The Agilent Technologies filter disc assembly is the most commonly used item that is used extensively in chemical laboratories, research facilities, manufacturing industries and pharmaceutical factories. This product is only available to U.S. Domestic Customers. For research use only, not…

  • Synonym: cuvette, spectrophotometer cuvette, spectrophotometry uv General Description Packaged in matched sets of 100 in styrofoam boxes to assure cuvettes are dust- and scratch-free. Note: These cuvettes are incompatible with some organic solvents. See transmission curve…

  • labForce® (powered by Thomas Scientific)

    Cylindrical Cells End windows fused to cylindrical body, of far UV silica, range 170 to 2,600 nm With Teflon stopper; 10 mm and 20 mm have single neck, longer sizes have 2 necks Light path length and minimum sample volume given in listings

  • Physical Configuration: Cylindrical cell Primary use: Absorbtion measurement with low absorbing samples Clear windows: Two Instrument: Can be used with spectrophotometers that can use cylindrical cells Pathlengths available: 50, 100mm Cell top: PTFE stopper with "ground…

Compare Tool

Select up to 3 products