Portable Water Quality Test Kits
They are invaluable when measuring the pH levels of water, which measures the acidity and alkalinity of the water and is important for assessing if water is suitable for drinking, agricultural, or industrial processes. Monitor the chlorine levels to ensure all water is disinfected correctly and safe for consumption.
Some water quality test kits can also identify the presence of harmful bacteria, which are indicators of water contamination and potential health risks.
Portable water testing kits are available in multiple forms, including test strips, chemical reagent kits, and more. Suitable for different types of water sources, including drinking water, pool, or environmental monitoring applications.
-
Nitrate ColorQ TesTabs
LaMotteThe LaMotte 0 - 15 ppm ColorQ nitrate TesTabs are suitable for use with ColorQ and ColorQ 2x test kits. They are mainly used in research facilities and chemical laboratories to conduct wide range of experiments. They are easy and convenient to use.
-
Method: colorimetric with test strips and reagent 3 - 10 - 30 - 100 mg/l CrO4 MQuant™ UN Number: UN3316 Storage: Store at +15°C to +25°C. Storage class: 8B Non-combustible, corrosive hazardous materials Hazard: Corrosive The chromate test…
-
Protects water baths and other water systems against the growth of algae, bacteria, molds and biofilms. Just 2ml per liter of water adds a blue tint which will fade after about 3 months reminding you to change the water and add new conditioner. Protects pumps and thermostats and helps…
-
Storage: Store at +15°C to +25°C. Precautionary Statement(s): P201: Obtain special instructions before use. P305 + P351 + P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P308 + P313: IF exposed…
-
Reagents Chlorine is the most widely used disinfectant for drinking water and is also important for sanitizing swimming pools, cooling towers, other industrial equipment and treatment of wastewater. Its measurement and control are vital for both safety and economic reasons. Many Hach chlorine…
-
Formaldehyde CHEMets Kit
CHEMetricsFormaldehyde, a toxic substance, is used in the following applications: metal plating baths, textile treatments, biological specimen preservatives, and disinfectants of medical equipment. Commercial formaldehyde gas is readily soluble in water. The Purpald Method Reference:…
-
Chlorine Test Kits
LaMotteDPD Tablet Octa-Slide (9859G42) Sufficient for 50 tests Employs DPD tablet method: EPA- accepted method for NPDWR Octa-Slide has color standards representing 0.2, 0.4, 0.6, 0.8, 1.0, 1.5, 2.0 and 3.0 ppm Cl Low Range Octet Comparator (9859H10) Employs DPD tablet…
-
Iron (Total & Ferrous) Vacu-vials Kit
CHEMetricsIron is present in nature in the form of its oxides, or in combination with silicon or sulfur. The soluble iron content of surface waters rarely exceeds 1 mg/L, while ground waters often contain higher concentrations. The National Secondary Drinking Water Standard for iron is 0.3 mg/L, as iron…
-
Lovibond® Tablet Reagent
LovibondThe DPD method is elementary for the determination of chlorine and for the correct dosing of the water care product. The DPD No.1 tablet is used to determine the free chlorine. The tablet is placed in a cuvette with a few drops of the water sample and crushed, sample water is added and mixed by…
-
Method Dissolved carbon dioxide (CO2) is naturally present as a result of animal respiration, the decay of organic matter, and the decomposition of certain minerals. It is the major source of acidity in unpolluted water samples. Surface waters typically contain less than 10 ppm…
-
Arium Consumables & Accessories
SartoriusConsumables & accessories for Sartorius Arium laboratory water systems. Arium® Smart Station flexible remote dispenser Ultrapure Water for benchtop or wall-mounted installation. The Arium® Smart Station is designed for flexible remote dispensing of ultrapure water directly at the…
-
Hardness Kit
LaMotteThis kit tests for Calcium Hardness in fresh or salt water. Includes inhibitors to eliminate metal interferences. All results are as CaCO3 Range/sensitivity is 0-200 ppm/4 ppm CaCO3, 0-2,500 ppm by dilution Applications: Environmental Education, Food and…
-
Hardness is a measure of the mineral content of water. Calcium and magnesium are the most common minerals that contribute to hardness. Hard water causes scaling in boilers and other industrial equipment, and diminishes the effectiveness of soaps and detergents. The EDTA Method (Total) …
-
Method: colorimetric with test strips and reagents 10 - 25 - 50 - 100 - 250 mg/l Al MQuant™ UN Number: UN1814 Storage class: 8B Non-combustible, corrosive hazardous materials Storage: Store at +15°C to +25°C. Hazard: Corrosive Aluminium compounds are…
-
-
Test Kit Components
LaMotteDirect Reading Titrator, Syringe Type For use in LaMotte field titration kits as well as in standard laboratory procedures such as dilutions and solution dispensing Plunger and barrel of propionate plastic; barrel has Luer slip tip Capacity 1 mL All-purpose…
-
-
-
Iron is present in nature in the form of its oxides, or in combination with silicon or sulfur. The soluble iron content of surface waters rarely exceeds 1 mg/L, while ground waters often contain higher concentrations. The National Secondary Drinking Water Standard for iron is 0.3 mg/L, as iron…
-
Urban Water Test Kit
LaMotteTest tap water from any source and study the impact of urban water on the city’s environment. "Wet in the City," a hands-on kit, introduces the basic concepts of water chemistry–even to kids as young as third grade! Non-hazardous TesTabs® make "Wet in the City" an…
-
DEHA Titrets Kit
CHEMetricsDissolved oxygen in boiler system water causes corrosion and pitting of metal surfaces, which can lead to boiler inefficiency, equipment failure, and system downtime. DEHA (N,N-Diethylhydroxylamine) is added to boiler system water as an oxygen scavenger to keep the dissolved oxygen levels as low as…
-
MColortest™ pH Test Phenol red solution
MilliporeSigmapH: 7.0 - 7.3 (H2O, 20°C) Solubility: (20°C) soluble Density: 0.99 g/cm3 (20°C)
-
DEHA Test Kit
LaMotte4790 OctaSlide Comparator For determining Diethylhydroxylamine (DEHA) concentrations by way of iron reduction method Octa-Slide comparator provides 8 standards between 0.05-1.5 ppm Three reagents perform 100 tests
-
Spectroquant® Fluoride Test Method: photometric
MilliporeSigmaPrecautionary Statement(s): P210: Keep away from heat/sparks/open flames/hot surfaces. - No smoking. P240: Ground/bond container and receiving equipment. P305 + P351 + P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do.…
-
Spectroquant® COD Cell Test
MilliporeSigmaAll necessary reagents for the analysis are contained in the cells Considerate packaging design protects the cells from fluctuation even in unfavorable environment Elimination of possible mistakes through barcode-system
-
Ammonia Vacu-vials Kit, Range: 0-7.00 ppm
CHEMetricsLow-level ammonia nitrogen may be naturally present in water as a result of the biological decay of plant and animal matter. Higher concentrations in surface waters can indicate contamination from waste treatment facilities, raw sewage, industrial effluents (particularly from petroleum refineries),…
-
Cyanide (Free) CHEMets Kit
CHEMetricsCyanide is used in many chemical and refining processes. It is found in effluent from electroplating and metal cleaning operations, coke ovens, steel manufacturing facilities, and gas scrubbers. Although cyanide can be safely removed by alkaline chlorination, its acute toxicity to aquatic life…
-
Detergents SAM Kit
CHEMetricsDetergents can be introduced into the water supply by industry, soap manufacturers, and private households. Environmental analysts often include a determination of anionic detergents when assessing surface water pollution. The Methylene Blue Method References: USEPA Methods for…
-
POOL MGR. Kit
LaMotteThe special rugged POOL MGR. kit series is for the public pool operator. The precise Octa-Slide 2 comparator system is used to comply with regulatory standards. The POOL MGR. series includes diagrammed instructions, saturation index calculator, water quality handbook, and the reliable Octa-Slide 2…
-
Total Hardness Test Kit
LaMotteApplications: Industrial Water Boiling and Cooling, Water and Wastewater This kit tests for Total Hardness using the Dropper Bottle Method. All results are as CaCO3. Range/sensitivity is 1 drop = 2, 5, or 10 ppm CaCO3.
-
The Lovibond® calcium hardness calcio no. 1/no. 2 tablet set is suitable for use in research facilities and chemical laboratories to conduct wide range of experiments. It is available in sturdy bottle that endures heavy and rigorous usage. It contains 100 tablets.
-
SCUBA II COMBI-PACK
LovibondINCLUDES: 20 DPD NO. 1 TABLETS AND 10 TABLETS EACH DPD NO. 3, PHENOL RED PHOTOMETER, CYA TEST & ALKA-M